How To Operate The Nova ViPLex Software

1. Ensure the computer and the playback box are on the same LAN (connected to the same router via Ethernet or WI-FI)or connect the computer directly to the playback box’s Ethernet port via a network cable. The default IP address for the playback box is 192.168.0.10, configure the computer’s IP address to be within the same subnet.

2. Power on the playback box, the screen parameters have already been configured and saved using Nova LCT.

3. Software: download ViPlex Express(desktop vision)from the Nova official website.

1. Open the software and select a mode.

Launch the software and choose one of the two options:

(1)Local playback: the computer directly outputs the video (synchronized, the computer must remain on)

(2)Asynchronous terminal: content is downloaded to the playback box, which then plays it automatically while offline(most common method)

⭐️For LED advertising screens, an asynchronous terminal is generally the preferred choice.

II.Search for and connect to the playback device box.

(1)Go to [ Terminal Management] > [Search Terminals] on the left, the TB/Taurus box will be automatically detected on the local network.

(2)Select the device and log in the default username is admin and the password is 123456.

(3)After successfully logging in, you can view screen status remotely power the device on or off, adjust brightness and volume, and schedule automatic power on/off.

⭐️FAQ:Unable to fine the controller box.

①Firewall disabled. ②IP network segments match. ③Ethernet cable/outer functioning correctly. ④Direct connection to the box’s AP. Connect the computer to the box’s built in WI FI (SSID details are on the label on the controller box)